手机网站
全国统一服务热线: 400 800 5549
产品中心 Products
MKT 84

MKT 84

项目介绍:

MKT Suppression Capacitor

with axial leads

Class X2

acc. DIN EN 60384-14 / IEC 60384-14

 

事宜人群:
产品信息

Characteristic

long life construction with internal series-connection and Aluminium metallization

good long term stability

RoHS Compliant 2011/95/EC

 

Dielectric: Polyester-Film (Polyethylenterephthalat-Film)

Electrodes: Vacuum deposited Aluminium with intern series connection

Coating: Plastic wrapped, epoxy resin sealed, flame retardant

Leads: Tinned wire Temperature range: -40°C to +100°C

Test classification: 40/100/21 acc. to IEC 60068-1

Flammability: Category C Rated voltage: 275 Vac, 50/60 Hz

Test voltage: 1 185 Vdc, 2 s (between terminations) 2 050 Vdc, 2 s (between interconnected terminations and case / foil method)

 

Insulation values Ri resp- : Ri  15 000 M for CR  0,33 µF   5 000 s for CR > 0,33 µF

Measuring procedure: 100 Vdc, 1 Min., 20°C

Capacity values: Series E12 acc. IEC 60063

Capacitance tolerance: 20%(M), 10%(K)

Dissipation factor tan (at 20°C):  8 * 10-3 at 1 kHz  15 * 10-3 at 10 kHz

Discharge test: 100 V/µs

Resistance to soldering heat: Bath temperature max. 260°C, duration max. 10 s, method Tb acc. IEC 60068-2-20

 

Hot Products / 热卖产品 More
2015 - 12 - 15
产品制造工艺符合MIL 18546和IEC 115的要求,此散热器表面安装设计可实现实现最大散热性能。• 高功率容量• 绕线达最大脉冲能力• 阻值范围:R005 ~ 100K• 接受定制• 符合RoHS
2015 - 10 - 22
内置高CMR光电耦合器内置短路保护器(定时器操作和复位电路)调整时间来控制短路检测的能力输入输出隔离电压:2500vrms 1min
2015 - 10 - 22
光电耦合器的输入和输出之间的电气隔离(维索= 2500vrms 1min)双电源驱动技术内置短路保护电路(带故障的引脚)TTL兼容的输入接口
Copyright ©2011 - 2015 上海井诚机电设备有限公司
分享  :